Product overview
The DC Charging Gun Comprehensive Test System is a fully automated solution designed to verify the functionality of EV charging guns in compliance with Chinese, European, and American standards. Each charging gun can be assigned a unique QR code, with all test results automatically recorded and compiled into reports. Passing results can be instantly printed, ensuring clear and traceable documentation.
With its one-click full-function testing, the system delivers high efficiency, reduces manual workload, and is especially ideal for batch inspections in manufacturing environments. This reliable and user-friendly system helps factories improve productivity while guaranteeing consistent quality control.
Technical Parameter
Power input | Single-phase AC 220V/50Hz; |
Air supply input | 0.6MPa; |
Control system | PLC + industrial computer |
Built-in resistance test range | 1-5000Ω, with an accuracy of 1%. |
Thermistor test range | 100-50,000Ω, 2% accuracy. Set upper and lower limits to determine if the on-resistance is good. |
Drive voltage | DC12V. Positive and negative voltage outputs are available to activate or disconnect the connector. Switch contact continuity monitoring is available to determine if the device is good or bad. |
Single-phase tests | L-N, L-E, and E-N; three-phase tests: L1/L2/L3/E-N, L1/L2/L3/N-E, N/L2/L3/E-L1, L1/N/L3/E-L2, and L1/L2/N/E-L3; DC tests: positive-negative, positive-ground, and negative-ground. |
Insulation Voltage | DC 100-1000V (variable setting); |
Lower Limit | 1MΩ to 1GΩ (variable setting); |
Accuracy | ±5%; |
DC tests | positive-negative, positive-ground, and negative-ground. |
Withstand voltage | DC 0-6kV, adjustable; |
Leakage current limit | DC 0.01mA-5mA, adjustable; |
Accuracy | ±1.5% + 3 digits; |
Display | Digital display indicates current voltage; |
Voltage regulation | Automatic programmable; |
Alarm detection | When the leakage current value exceeds the set value, the sample is considered defective. |
Test Station | One station, testing one product at a time. Both the head and tail gun mounts are installed on the equipment. |
Gun Plug | Available with European standard DC gun mounts, and American standard DC gun mounts. |
Dimensions | W900mm x D800mm x H1800mm. The base is equipped with locking casters. |
Weight | Approximately 300kg. |
Details